Resultado da pesquisa (8)

Termo utilizado na pesquisa Doppler ultrasonography

#1 - B-mode and Doppler ultrasonography in the assessment of the common carotid arteries of equines and mules and the relation with body mass, age and neck circumference

Abstract in English:

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.

Abstract in Portuguese:

Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.


#2 - Abdominal B-mode and Doppler ultrasonography of chemically restrained agouti (Dasyprocta prymnolopha Wagler, 1831)

Abstract in English:

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm. The stomach was placed to the left the spleen and to the right of the proximal intestine and the transversal colon and the walls were 0.16±0.05cm thick. The abdominal aorta was 0.43±0.04cm in diameter and showed 95.2±2.16cm/s vascular flow. This study characterized agouti organs and abdominal blood vessels by B scan and Doppler ultrasound, that permitted definition of the size, shape, position, echogenicity and echotexture of the anatomic constituents and established reference values for the vascular network and blood flow in the species.

Abstract in Portuguese:

As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres – NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas. A espessura do pâncreas foi de 0,51±0,1cm e o ducto pancreático mediu 0,12±0,02cm. O estômago relaciona-se à esquerda com o baço e a direita com o duodeno proximal e colón transverso. Sua espessura de parede mensurada foi de 0,16±0,05cm. A aorta abdominal possui diâmetro de 0,43±0,04cm e fluxo vascular de 95,2±2,16cm/s. Este estudo caracterizou os órgãos e vasos sanguíneos abdominais de cutias, por meio de ultrassonografia modo B e Doppler, o que permitiu definir o tamanho, formato, posição, ecogenicidade, ecotextura dos constituintes anatômicos, além de estabelecer valores de referência para a rede vascular e fluxo sanguíneo na espécie.


#3 - Uterine vasculature of pregnant mares of donkey and stallion through the Doppler ultrasonography spectral mode, 37(8):877-882

Abstract in English:

ABSTRACT.- Lemos S.G.C., Campos D.G., Ferreira C.S.C., Balaro M.F.A., Cunha L.E.R., Pinna A.E. & Brandão F.Z. 2017. [Uterine vasculature of pregnant mares of donkey and stallion through the Doppler ultrasonography spectral mode.] Vascularização uterina de éguas prenhes de jumento e de garanhão monitoradas por ultrassonografia Doppler. Pesquisa Veterinária Brasileira 37(8):877-882. Faculdade de Veterinária, Universidade Federal Fluminense, Rua Vital Brazil Filho 64, Vital Brazil, Niterói, RJ 24230-340, Brazil. E-mail: binagaiacl@gmail.com This study aimed to evaluate and describe the ultrasonographic findings of uterus of pregnant mares of different ages, mated by either ass or stallion, using the spectral Doppler ultrasonography, aiming to characterize the resistance (RI) and pulsatility (PI) Doppler indices up to 154 days of pregnancy. A total of 20 mares in reproductive age of non-defined breed were used. The evaluations were performed in uterine arteries. There was no interaction between RI and PI values obtained in uterine horns (that initiated or not the pregnancy) with time of pregnancy (P>0.05), thus, data were discussed separately. There were no differences between RI and PI evaluations when compared to the uterine horns that initiated or not the pregnancy (P>0.05). A time effect was observed (P<0.05) on PI, when D70 presented lower averages than D0, D7, D14 and D21. There was no time effect (P>0.05) on RI. Pregnant mares mated by asses presented higher uterine vascularization in non-pregnant horn than pregnant mares mated by stallions. With the exception of RI in non-pregnant horn, there was a female age effect on the side of pregnancy (P<0.05), where aged mares in both – pregnant and non-pregnant horns – showed higher PI and RI, so less vascularized. It is possible to conclude that the uterine vascularization did not present any difference between uterine horns. There is an increase in the uterine vascularization on the 70th day of pregnancy. Pregnant mares mated by assess presented higher uterine vascularization when compared to those mated by stallions. Mares aging over 15 years old presented lower uterine vascularization, when compared to those younger.

Abstract in Portuguese:

RESUMO.- Lemos S.G.C., Campos D.G., Ferreira C.S.C., Balaro M.F.A., Cunha L.E.R., Pinna A.E. & Brandão F.Z. 2017. [Uterine vasculature of pregnant mares of donkey and stallion through the Doppler ultrasonography spectral mode.] Vascularização uterina de éguas prenhes de jumento e de garanhão monitoradas por ultrassonografia Doppler. Pesquisa Veterinária Brasileira 37(8):877-882. Faculdade de Veterinária, Universidade Federal Fluminense, Rua Vital Brazil Filho 64, Vital Brazil, Niterói, RJ 24230-340, Brazil. E-mail: binagaiacl@gmail.com Este estudo teve como objetivo analisar e descrever os achados ultrassonográficos do útero de éguas gestantes de diferentes idades, de jumento e garanhão, utilizando a técnica de ultrassonografia Doppler Espectral, visando caracterizar os índices de resistência (RI) e pulsatilidade (PI) até 154 dias de gestação. Foram utilizadas 20 éguas em idade reprodutiva, sem raça definida. As avaliações foram realizadas nas artérias uterinas. Não foi constatada interação entre os valores de RI e PI obtidos nos cornos uterinos (que iniciaram ou não a gestação) com o tempo da gestação (P>0,05), desta forma os dados foram discutidos separadamente. Não foram encontradas diferenças entre as avaliações de RI e PI quando comparado os cornos que iniciaram ou não a gestação (P>0,05). Verificou-se efeito de tempo (P<0,05) sobre o PI, onde no D70 foi constatada a menor média quando comparado aos tempos D0, D7, D14 e D21. Não f oi encontrado efeito de tempo sobre o RI (P>0,05). As éguas gestantes de jumento apresentaram maior vascularização uterina no corno não gestante, que as éguas gestantes do garanhão. Com exceção do RI no lado não gravídico, foi verificado efeito de idade da fêmea sobre o lado da gestação (P<0,05), onde as éguas idosas, tanto no corno que iniciou a gestação e o contralateral, tiveram PI e RI mais altos, ou seja, menos vascularizados. Concluiu-se que a vascularização uterina não apresentou diferença entre os cornos uterinos. Há um aumento da vascularização uterina no 70º dia de gestação. Éguas gestantes de jumentos apresentaram maior vascularização uterina, quando comparada às éguas gestantes de garanhões. Éguas com idade acima de 15 anos apresentaram menor vascularização uterina, quando comparadas com idade inferior a 15 anos.


#4 - B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media, 37(7):759-772

Abstract in English:

ABSTRACT.- Martín C.M., Kogika M.M., Miyashiro S.I. & Fonseca-Pinto A.C.B.C. 2017. [B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media.] Ultrassonografia modo B e Doppler na avaliação renal de cães submetidos à tomografia computadorizada após administração intravenosa de diferentes meios de contraste iodado. Pesquisa Veterinária Brasileira 37(7):759-772. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Contrast-induced nephropathy (CIN) is an acute disease, secondary to intravascular administration of iodinated contrast media (ICM). The most important mechanisms of this nephropathy are intrarenal prolonged vasoconstriction, medular hypoxia, and ischemia associated with renal tubular damage due to contrast cytotoxicity. Owing to the limited information available in veterinary literature regarding these mechanisms this study aims to compare the renal effects of intravenous administration of two nonionic ICM of different osmolarities in groups of dogs with risk factors for CIN development, by using a B-mode, color, power- and pulsed-wave Doppler ultrasonography, and other laboratory tests, in order to indirectly estimate the nephrotoxic potential of each contrast. The following two groups were established according to the nonionic ICM used: the GIH group [11 dogs administered iohexol (low osmolarity)] and the GID group [seven dogs administered iodixanol (iso-osmolarity)]. Both the groups were administered the same dose (600mgI/kg/IV). The following renal aspects were evaluated before administration of ICM (baseline) and after 1h30min, 24h, and 48h: renal morphometry (length and volume), renal morphology, cortical echogenicity, renal perfusion, and intrarenal vascular resistance (resistive and pulsatility indices); in addition, urinalysis was performed, and urinary gamma-glutamyl transferase:creatinine ratio (GGT:C), urinary protein:creatinine ratio (UPC), and serum creatinine were also measured. Both groups showed similar characteristics with respect to the length, volume, UPC ratio, urinalysis, and serum creatinine levels. No similarity was observed with respect to the pulsatility index (PI) in both the groups and there were no significant differences between baseline and 1h30min, 24h and 48h time points. With respect to the IR and urinary GGT:C, both groups showed no similarity, and significant increases were observed in the resistive index (RI) and urinary GGT:C only in the GIH group, 1h30min after contrast administration. In conclusion, RI can be used to monitor intrarenal hemodynamics, and along with the urinary GGT:C, revealed that iohexol had higher nephrotoxic potential than iodixanol. Thus, iodixanol is considered a favorable option for dogs with risk factors for CIN development.

Abstract in Portuguese:

RESUMO.- Martín C.M., Kogika M.M., Miyashiro S.I. & Fonseca-Pinto A.C.B.C. 2017. [B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media.] Ultrassonografia modo B e Doppler na avaliação renal de cães submetidos à tomografia computadorizada após administração intravenosa de diferentes meios de contraste iodado. Pesquisa Veterinária Brasileira 37(7):759-772. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br A nefropatia induzida por contraste (NIC) é uma doença de caráter agudo, secundária à administração intravascular de meios de contraste iodado (MCI). Dentre os mecanismos fisiopatológicos desta enfermidade destacam-se a vasoconstrição intrarrenal prolongada, consequente redução da perfusão renal, hipóxia e isquemia medulares, associada ao dano tubular renal devido à citotoxicidade do contraste. Frente à existência de poucas informações relacionadas a estes mecanismos na literatura médico-veterinária, objetivaram-se comparar os efeitos renais da administração intravenosa de MCI não iônicos de diferentes osmolaridades, em grupos de cães com fatores de risco para o desenvolvimento da NIC, por meio das avaliações ultrassonográficas modo B, Doppler colorido, de amplitude e pulsado, pareada aos exames laboratoriais, a fim de estimar indiretamente o potencial nefrotóxico de cada contraste. Constituíram-se dois grupos de acordo com o MCI utilizado: o grupo GIH [11 cães receberam iohexol (baixa osmolaridade)] e o grupo GID [sete cães receberam iodixanol (isosmolar)]. Administrou-se a dose de 600mgI/kg/IV em ambos. Avaliaram-se os seguintes aspectos renais antes da administração do MCI (momento basal) e após 1h30min, 24 horas e 48 horas: morfometria (comprimento e volume), morfologia, ecogenicidade cortical e perfusão renais e resistência vascular intrarrenal (índices hemodinâmicos de resistividade e pulsatilidade). Realizou-se ainda exame de urina e se mensuraram as razões gama-glutamil transferase:creatinina (GGT:C) e proteína:creatinina (RPC) urinárias e a concentração sérica de creatinina. Os grupos apresentaram comportamentos similares para comprimento, volume, RPC, exame de urina e creatinina sérica. Em relação ao índice de pulsatilidade (IP), os grupos apresentaram comportamentos não similares, mas sem diferenças significantes entre o momento basal e os demais. Para o índice de resistividade (IR) e a razão GGT:C urinária, os grupos revelaram comportamentos não similares e se constataram aumentos significantes do IR e da razão GGT:C urinária no período de 1h30min após a administração do contraste, somente para o grupo que recebeu iohexol. Concluiu-se que o IR pode ser utilizado para monitorar a hemodinâmica intrarrenal, visto que junto com a razão GGT:C urinária, demonstrou a existência de maior potencial nefrotóxico do iohexol, quando comparado ao iodixanol. Dessa forma, considera-se o uso do iodixanol, opção favorável para cães com fatores de risco para o desenvolvimento da NIC.


#5 - Mammary artery Doppler ultrasonography of Brazilian Bergamasca dairy ewe lambs under the influence of two different feeding plans, 37(2):179-182

Abstract in English:

ABSTRACT.- Dantas A., Siqueira E.R., Fernandes S., Oba E., Machado V.M.V., Castilho A.M., Sartori M.M.P. & Santos R.V. 2017. Mammary artery Doppler ultrasonography of Brazilian Bergamasca dairy ewe lambs under the influence of two different feeding plans. Pesquisa Veterinária Brasileira 37(2):179-182. Departamento de Produção Animal, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Rua José Barbosa de Barros 1780, Botucatu, SP 18618-000, Brazil. E-mail: dantas.vet@gmail.com Blood supply of mammary gland is extremely important, since it is a crucial factor in the mammary tissue development. The objective of this study was to describe and assess main mammary artery hemodynamic characteristics of lambs with two growth rates, using Doppler ultrasound. Two experimental groups, A and B, (n=10) of female Brazilian Bergamasca lambs were kept under the same management conditions and facilities. There were two phases: Phase 1, from 90 days of age until onset of puberty; Phase 2, from puberty until 1 year of age. During phase 1, a specific diet was formulated to each experimental group to obtain two different average daily gains: 150g, for treatment A, and 250g, for treatment B. During phase 2, there was no difference on the diet offered to both groups. Every 14 days, all animals were weighed and their body condition score was evaluated. Every 60 days, ultrasound exams (Doppler) of mammary artery were performed to obtain resistance and pulsatility indexes. Treatment B lambs showed higher weight gain and higher body condition score (P<0.05). However, for resistance and pulsatility indexes, there was no difference between treatments (P>0.05). Hemodynamic values remained constant, independent of diet or body development presented by the animals. Obtained data is valuable information on Bergamasca ewe lambs development.

Abstract in Portuguese:

RESUMO.- Dantas A., Siqueira E.R., Fernandes S., Oba E., Machado V.M.V., Castilho A.M., Sartori M.M.P. & Santos R.V. 2017. Mammary artery Doppler ultrasonography of Brazilian Bergamasca dairy ewe lambs under the influence of two different feeding plans. Pesquisa Veterinária Brasileira 37(2):179-182. Departamento de Produção Animal, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Rua José Barbosa de Barros 1780, Botucatu, SP 18618-000, Brazil. E-mail: dantas.vet@gmail.com O suprimento sanguíneo da glândula mamária é extremamente importante, uma vez que é um fator crucial para o desenvolvimento do tecido mamário. Assim, a necessidade de registro dos parâmetros de fluxo sanguíneo arterial é evidente. O objetivo do estudo foi descrever e avaliar as principais características hemodinâmicas da artéria mamária de cordeiras submetidas a diferentes taxas de crescimento, usando o ultrassom Doppler. Dois grupos experimentais, A e B, (n=10) de cordeiras da raça Bergamácia brasileira foram mantidas sob as mesmas condições de manejo e instalações. O estudo foi dividido em diferentes fases, sendo: Fase 1, de 90 dias de idade até o início da puberdade; Fase 2, desde a puberdade até 1 ano de idade. Durante a fase 1, dietas específicas foram formuladas para cada grupo experimental, a fim de obter duas médias diferentes de ganho de peso diário: 150g, para o tratamento A, e 250g, para o tratamento B. Durante a Fase 2, não houve diferença na dieta oferecida para os dois grupos. A cada 14 dias, todos os animais foram pesados e determinado o escore de condição corporal. A cada 60 dias, exames de ultrassom (Doppler) da artéria mamária foram realizados a fim de calcular os índices de resistência e pulsatilidade. As cordeiras do tratamento B registrou maior ganho de peso e escore de condição corporal (P<0,05). No entanto, não houve diferença para os índices de resistência e pulsatilidade entre os tratamentos (P>0,05). Os valores hemodinâmicos permaneceram constantes, independente da dieta ou o desenvolvimento do corpo apresentada pelos animais. Assim, os dados obtidos são informações valiosas sobre o desenvolvimento da raça a que se refere.


#6 - B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation, 35(9):801-810

Abstract in English:

ABSTRACT.- Martín C.M., Souto C.K., Ferrante B. & Fonseca-Pinto A.C.B.C. 2015. [B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation.] Ultrassonografia modo B e Doppler na avaliação renal de cães após administração intravenosa de meio de contraste iodado: validação da técnica. Pesquisa Veterinária Brasileira 35(9):801-810. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Iodinated contrast media can provide hemodynamic effects related to prolonged intrarenal vasoconstriction and reduced perfusion, predisposing to hypoxia and medular ischemia. Changes in the renal vascular resistance may represent the first sign of impaired renal function. Pulsed wave Doppler sonography is low cost, non-invasive and allows renal hemodynamic evaluation by resistivity (RI) and pulsatility (PI) indices. However in dogs, spectral Doppler waveform may be hard to obtain due to scanning difficulties and lack of signal Doppler. This fact occurs mostly in the right kidney because of its cranial and dorsal position in the abdominal cavity and may prolong the exam. The purpose of this study is to prove that the pulsed wave Doppler interrogation of the canine left kidney intrarenal arteries represent the renal hemodynamic effects of intravenous administration of iodinated contrast media and is not necessary to perform the exam in both kidneys. Right and left kidneys of six adult dogs were evaluated at four different times: before intravenous contrast infusion and after 1.5 hours, 24 hours and 48 hours, subjectively by using renal morphology, cortical echogenicity and renal perfusion, and objectively by using renal length, renal volume and intrarenal vascular resistance (RI and PI). No significant differences were noted between the parameters assessed by B mode and Doppler sonography of the right and left kidney in each evaluated moment. Thus, it was noted that pulsed wave Doppler sonographic evaluation of the left kidney represented the renal hemodynamic response of intravenous iodinated contrast media administration, only if both kidneys presented similar morphometry, morphology, cortical echogenicity, and perfusion during the first assessment.

Abstract in Portuguese:

RESUMO.- Martín C.M., Souto C.K., Ferrante B. & Fonseca-Pinto A.C.B.C. 2015. [B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation.] Ultrassonografia modo B e Doppler na avaliação renal de cães após administração intravenosa de meio de contraste iodado: validação da técnica. Pesquisa Veterinária Brasileira 35(9):801-810. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Meios de contraste iodado podem promover efeitos hemodinâmicos relacionados à vasoconstrição intrarrenal prolongada e redução da perfusão, predispondo à hipóxia e isquemia medular. Alterações de resistência vascular renal podem representar os primeiros sinais de mudança funcional desse órgão. A técnica Doppler pulsado é considerada acessível, não invasiva e permite avaliar a dinâmica vascular dos rins, por meio da aferição dos índices de resistividade (IR) e pulsatilidade (IP). Contudo, na espécie canina, a aquisição de traçados espectrais pode ser penosa devido às dificuldades de varredura e captação de sinal Doppler, sobretudo em relação ao rim direito, devido à sua localização dorsocranial na cavidade abdominal, o que prolonga substancialmente a realização do exame. O objetivo deste estudo é comprovar que a avaliação Doppler pulsado das artérias intrarrenais do rim esquerdo de cães representa a repercussão hemodinâmica renal da administração intravenosa de meios de contraste iodado não sendo necessária a realização do exame nos dois rins. Foram avaliados ambos os rins de seis cadelas adultas em quatro momentos distintos: antes da infusão intravenosa do contraste radiológico e após 1,5 horas, 24 horas e 48 horas, por meio da análise subjetiva da morfologia, ecogenicidade cortical e grau de perfusão renais e análise objetiva do comprimento, volume e resistência vascular intrarrenais (IR e IP). Os parâmetros avaliados ao modo B e Doppler dos rins direito e esquerdo não apresentaram diferenças estatisticamente significativas entre si em cada momento avaliado. Assim, constatou-se que o exame ultrassonográfico Doppler pulsado do rim esquerdo representou a repercussão hemodinâmica renal da aplicação intravenosa de meios de contraste iodado, desde que morfometria, morfologia, ecogenicidade cortical e perfusão de ambos os rins fossem consideradas semelhantes na abordagem ultrassonográfica inicial.


#7 - Ovarian and uterine periovulatory Doppler ultrasonography in bitches, 33(9):1144-1150

Abstract in English:

ABSTRACT.- Barbosa C.C., Souza M.B., Scalercio S.R.R.A., Silva T.F.P., Domingues S.F.S. & Silva L.D.M. 2013. Ovarian and uterine periovulatory Doppler ultrasonography in bitches. Pesquisa Veterinária Brasileira 33(9):1144-1150. Laboratório de Reprodução de Carnívoros, Universidade Estadual do Ceará, Campus do Itaperi, Av. Paranjana 1700, Itaperi, Fortaleza, CE 60740-903, Brazil. E-mail: lucia.daniel.machado@hotmail.com This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm3, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.

Abstract in Portuguese:

RESUMO.- Barbosa C.C., Souza M.B., Scalercio S.R.R.A., Silva T.F.P., Domingues S.F.S. & Silva L.D.M. 2013. Ovarian and uterine periovulatory Doppler ultrasonography in bitches. [Ultrassonografia Doppler ovariana e uterina em cadelas.] Pesquisa Veterinária Brasileira 33(9):1144-1150. Laboratório de Reprodução de Carnívoros, Universidade Estadual do Ceará, Campus do Itaperi, Av. Paranjana 1700, Itaperi, Fortaleza, CE 60740-903, Brazil. E-mail: lucia.daniel.machado@hotmail.com Este trabalho teve como objetivo descrever as características ultrassonográficas uterinas e ovarianas, e dopplervelocimétricas das suas artérias nos dias periovulatórios em cadelas. Quinze ciclos estrais em 10 animais foram avaliados. As características ultrassonográficas, índices de resistência (IR) e índices de pulsatilidade (IP) do útero e dos ovários em cada animal foram registrados 5 dias antes e depois da ovulação (D0). Os dados foram analisados estatisticamente e os resultados foram expressos em média ± erro padrão da média (P<0,05). Como resultados as características ultrassonográficas uterinas foram semelhantes em todos os ciclos e dias avaliados, tendo o corpo uterino um diâmetro médio de 0,85±0,02cm. Foi observado um aumento no volume dos ovários e nos diâmetros dos folículos, tendo os ovários um volume de 0,64±0,06cm3, e a cavidade dos folículos um diâmetro de 0,46±0,01cm no dia da ovulação. Após a ovulação, foi observado colapso dos folículos somente em alguns ciclos. A perfusão sanguínea uterina diminuiu dois dias antes da ovulação e permaneceu inalterada até a ovulação. Após a ovulação, houve um aumento gradual na perfusão das artérias uterinas e ovarianas, direcionando o fluxo de sangue para os ovários e aumentando a perfusão da artéria intra-ovariana um dia após a ovulação. Conclui-se que características específicas são observadas na imagem ultrassonográfica uterina e ovariana, e dopplervelocimétricas de suas artérias nos dias periovulatórios, e quando associadas permitem estimar com mais precisão o dia da ovulação.


#8 - Doppler ultrasonography in the renal evaluation of bitches diagnosed with pyometra before and after treatment with ovariohysterectomy, 33(5):635-642

Abstract in English:

ABSTRACT.- Santos R.V., Merlini N.B., Souza L.P., Machado V.M.V., Pantoja J.C.F. & Prestes N.C. 2013. [Doppler ultrasonography in the renal evaluation of bitches diagnosed with pyometra before and after treatment with ovariohysterectomy.] Ultrassonografia Doppler na avaliação renal de cadelas diagnosticadas com piometra antes e após o tratamento com ovariosalpingohisterectomia. Pesquisa Veterinária Brasileira 33(5):635-642. Departamento de Reprodução Animal e Radiologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Distrito de Rubião Júnior s/n, Botucatu, SP 18618-970, Brazil. E-mail: robertavaleriano@yahoo.com.br The aim of this study was evaluate the renal hemodynamics of bitches with pyometra by means of laboratory tests, ultrasound B mode and Doppler, before and after treatment with ovariohysterectomy (OSH). This study evaluated 30 bitches with pyometra, all were subjected to OSH (moment 1) and 20 were evaluated after 7 days (moment 2). The renal perfusion, the resistivity index (RI) of the main renal artery and the interlobar arteries (cranial, middle and caudal) were statistically different between times 1 and 2 (p<0,05). There was no statistical difference for renal perfusion between the left and the right kidney at the time 1 and 2. The correlations between the IR of the main artery and the variables used to determine renal function were stablished at the time 1. For the correlated variables: urea, creatinine, proteinuria, ratio GGT/creatinine and protein/creatinine were curvilinear and positive associations with the resistivity index of the main renal artery (p<0,05), however these correlations were considered medium and weak. Comparing the RI of the main renal artery with different scores of dehydration and renal perfusion, there was statistical difference, and show increased of resistance renal in bitches with moderate reduction in renal perfusion as well as in dehydrated bitches. Were evaluated several features of renal morphology in ultrasound B mode, however, only the presence of pelvic dilatation, medullary signal and other changes as infarcts areas and diffuse hyperechoic spots in the renal cortical and medullary were statistically different from one moment to the other, most frequently at the time 2. The results of this study show that the Doppler ultrasound can identify changes of reduction in renal perfusion by color Doppler and the increasing of the resistivity index of the renal arteries in some bitches with pyometra. As well as, the ultrasound B mode, although has non-specific changes, can detect progressive renal disorders in bitches with pyometra.

Abstract in Portuguese:

RESUMO.- Santos R.V., Merlini N.B., Souza L.P., Machado V.M.V., Pantoja J.C.F. & Prestes N.C. 2013. [Doppler ultrasonography in the renal evaluation of bitches diagnosed with pyometra before and after treatment with ovariohysterectomy.] Ultrassonografia Doppler na avaliação renal de cadelas diagnosticadas com piometra antes e após o tratamento com ovariosalpingohisterectomia. Pesquisa Veterinária Brasileira 33(5):635-642. Departamento de Reprodução Animal e Radiologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Distrito de Rubião Júnior s/n, Botucatu, SP 18618-970, Brazil. E-mail: robertavaleriano@yahoo.com.br O objetivo do presente estudo foi avaliar a hemodinâmica renal de cadelas com piometra por meio de exames laboratoriais, ultrassonografia Modo B e Doppler, antes e após o tratamento cirúrgico com ovariosanpigohisterectomia (OSH). Foram utilizadas 30 cadelas com diagnóstico de piometra, todas foram submetidas a OSH (momento 1) e 20 foram reavaliadas sete dias após a cirurgia (momento 2). A perfusão renal, o índice de resistividade da artéria renal principal e de cada artéria interlobar (cranial, média e caudal) foi estatisticamente diferente entre os momentos 1 e 2 (p<0,05). Não foi observada diferença estatística para a perfusão renal entre o rim direito e esquerdo no momento 1 e 2. As correlações entre o índice de resistividade da artéria renal principal e as variáveis utilizadas para verificar a função renal foram estabelecidas no momento 1. Para as variáveis correlacionadas ureia, creatinina, proteinúria, relação GGT/creatinina e proteína/creatinina ocorreram associações curvilíneas e positivas com o índice de resistividade da artéria renal principal (p<0,05), no entanto essas correlações foram consideradas de média e fracas. Ao comparar o IR da artéria renal principal com diferentes escores de desidratação e perfusão renal, este foi estatisticamente diferente, e demonstrou aumento da resistência renal em cadelas com moderada redução da perfusão renal, assim como em cadelas desidratadas. Foram avaliadas diversas características de morfologia renal na ultrassonografia Modo B, no entanto, somente as variáveis presença de dilatação de pelve, sinal da medular e outras alterações como áreas de infartos e pontos hiperecogênicos difusos na cortical e medular renal foram estatisticamente distintas de um momento para o outro, com maior frequência no momento 2. Os resultados do presente trabalho demonstram que a ultrassonografia Doppler pode identificar alterações de redução na perfusão renal, por meio do Doppler colorido e o aumento do índice de resistividade das artérias renais em cadelas com piometra. Assim como, a ultrassonografia modo B, embora apresente alterações inespecíficas, pode detectar alterações renais progressivas em cadelas com piometra.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV